PM10 Environmental Air Sampler Systems
Staplex®
PM10 High Volume Air
Samplers (Click
to open pdf literature file)
- Meets all of EPA's PM-10
performance specifications in Federal
- Reference Method
(RFPS1287-063)
- Hinged sampling chamber for
easy cleaning/greasing of collection shim
- Removable collection shim
prevents large particle bounce at high concentration sites
- Made in U.S.A.
Basic System includes PM10-SSI
Size Selective Inlet plus the following Staplex® components:
- Staplex® TFIA Series
High Volume Air Sampler,
- SH810 8"x10"
Filter Holder Assembly
- FPC810 Filter Paper Cassette
- FC-1ETM (110 VAC) or FC-2ETM
(220VAC) Constant Flow Controller
- with built-in Elasped Time
Indicator (99,999.99 hours mechanical,
non-resettable)
- SAM Aluminum Outdoor Shelter
Model PM10-1 Basic PM10 High
Volume Air Sampling System 115
VAC, 60 Hz
Model PM10-2 Basic PM10 High
Volume Air Sampling System 230
VAC, 50Hz
Required Filters:
Staplex® Type TFAQ810 Quartz Fiber Filters, 8" x 10"
(25 per box)
Size: 64"H
(163 cm) high x maximum 28" (71 cm) diameter
Net Weight: Base
with Basic Components: 45 lbs. (20.5 kg.) PM10 Size Selective
Inlet, 50 lbs. (23 kg.)
NOTE: Staplex® PM10 Size
Selective Inlet is available separately as Part No. PM10-SSI for
conversion of existing TSP (Total Suspend Particulate) High
Volume Air Sampling Systems to PM10 Systems. Above Basic System
Components are recommend to convert to a basic PM10 System
Additional Options:
Flow Recorder -
Models FR-1 and FR-2 -
Provides a permanent record of High Volume Air Sampler
performance during a 24-hour period. Specify Model FR-1 for 115
VAC; Model FR-2 for 230 VAC. (see
additional data sheet).
Filter Paper Cartridge - No.
FPC810 - Spare
cartridge to hold 8"x10" Filters, allows fast filter
changes in field operation and protects filter during
transportation
Timers
DTM-1 and
DTM-2 Digital 7-Day Timer - Turns
Air Sampler "ON" and "OFF" at set times, 24
hours a day, 7 days a week. All functions are digital and quartz
crystal controlled; digital clock with 1/4-in. LED display and
7.2 VDC re-chargeable stand-by battery; intuitive programming
format. Specify Model DTM-1 for 120 VAC, 60 Hz; Model DTM-2 for
230 VAC (specify 50 or 60 Hz when ordering).
(Click
to open pdf literature file)
MT-1 and MT-2
Mechanical 7 Day Timer Turns
Air Sampler "ON" and "OFF" at set times ±
15 minutes, 24 hours a day, 7 days a week. Specify Model MLT-1
for 120 VAC, 60 Hz; Model MLT-2 for 230 VAC, 50 Hz
Substitute
Options for FC-1ETM/FC-2ETM
FC-1 (115 VAC)
/ FC-2 (220 VAC)
Constant Flow Controller (without any timer)
FC-1MLT (115
VAC) / FC-2MLT (220 VAC)
same as FC-1, with built-in Mechanical 7-Day Timer and
non-resettable Elapsed Time Indicator,
ETI-1 (120 VAC)
/ETI-2 (220 VAC) Elapsed Time Indicator
- (without Flow Controller) Shows sampler
run time in hours and hundreths (99,999.99 hours,
mechanical non-resettable). (Re-settable
model ETI-1R is also available for 120 VAC.)
Calibration
Kit - Model CKHV810 - U.S.
EPA prescribed method for accurate calibration of High
Volume Air Samplers. U.S. EPA recommends
that High Volume Air Samplers be re-calibrated at least once per
year (or when major components such as the motor or flowmeter
are changed). Model CKHV810 can be used with 4" or 8"
x 10" filter holder assemblies. (see
additional data sheet)
Description
PRINCIPLE OF OPERATION:
Suspended particles in the air
are sampled at 40 ACFM through the circumferential inlet of the
PM10 Size Selective Inlet. The symmetrical design insures
wind-direction insensitivity, and the Inlet design and internal
configuration makes the collection efficiency independent of
wind speed from 0 to 36 kilometers per hour. The particles are
then accelerated through multiple circular Impactor nozzles. By
virtue of their larger momentum, particles greater than the 10
micron impactor cut-point impact onto the greased impaction
surface. The PM-10 particles smaller than 10 microns are carried
vertically upward by the air flow and down multiple vent tubes
to the 8-inch x 10-inch quartz fiber filter (Staplex® No.
TFAQ810), where they are collected. The large particles settle
out in the impaction chamber on the collection shim and are
removed/cleaned during prescribed maintenance periods.
The quartz fiber filter is
weighed before and after sampling. The weight increase is the
mass of particles smaller than 10 microns. The mass
concentration of PM-10 particles (micrograms per cubic meter) is
determined by dividing the particulate mass (micrograms) by the
sampled air volume (cubic meters). The FC-1 Series Electronic
Mass Flow Controller included in the system properly totalizes
the air volume by maintaining a constant flow rate of 40 ACFM
regardless of filter loading, atmospheric conditions and line
voltage
Inlet Collection Efficiency:
PM10 Inlet has a cut-point of 9.7 microns over a wind speed of 0
to 36 KPH.
Flow Rate: 40
cubic feet per minute (CFM), 1.13 cubic meters per minute.
Filter Media: 8-in.
x 10-in. (20 cm x 25 cm) quartz fiber filter media, Staplex®
No. TFAQ810 (25 per box)
Accuracy of Mass Flow Control
(@ 40 CFM): ± 2.5%
deviation over 24-hour sampling period.
Made in U.S.A.

 |