|
c fm = cubic feet per minute; cmm = cubic meters per minuteUse Model TFIA-4 with Portable Re-chargable Battery Pack
and Charger: Model TF24B Battery Pack (20 minute run time on full charge; 6 hour recharge time) shown on left with optional carrying case with shoulder strap Model TF24CU Battery Charger (110-125 VAC) for TF24B Battery Pack Model TF24CU Battery Charger (220-240 VAC) for TF24B Battery Pack Other special model High Volume Air Samplers also available. Gasoline and diesel generators available for TFIA (110-125 V) and TFIA-2 (220-230) Series High Volume Air Samplers. Request details. Specifications for TFIA Series: Dimensions: 8-1/2 " x 7-1/2 " x 7-1/2 (21.6 x 19.1 x 19.1 cm) Carrying weight: 10 lbs. (4.5 kg) Construction: Sturdy Lightweight Dural Main Housing Description Portable Air Sampler for indoor and outdoor sampling for all types of airborne particulates including environmental pollutants, nuclear and biohazards, industrial, governmental and military tests and studies, mine air hazards, factory dusts, chemical, radiological and toxicological analyses, as well as innumerable other types of research, quality control and testing applications. Principle of Operation Large volumes of air are drawn through a filter by a high-speed rotary motor. Particulate matter in the air collects on various types and sizes of filter papers including Glass Fiber Filter Media. Standard Features Universal motor, Pump, Variable Orifice Flowmeter calibrated 0-70 CFM or 0-2 CMM; 4" (10.16 cm) diameter Filter Holder Assembly, Filter Support Rod and Stainless Steel Mesh Adapter, carrying handle, on/off current toggle switch, 8 foot (38 cm) grounded cordset. Analysis of Collected Samples Filters can be analyzed gravimetrically, by weighing, taring, ashing, spectrography, atomic absorption, comparator, microscopic count, chromatography, atomic colorimetric assay, and gammaray spectroscopy, x-ray fluorscopy and neutron activation etc., to identify pollutants and measure their concentrations. Operation Proper filter is inserted into appropriate filter holder of air sampler and sampler is then ready for test operations. Initial flow rate and sampling time are recorded. Flow rate is governed by size and type of filter used. (See Chart A Filters) The Staplex SH4 4" Diameter Filter Holder Assembly, is equipped with filter support rod to be used as back support for Staplex TFA2133 filters. In addition. when using Staplex TFA41 Filter Paper and Staplex TFAGF41 Glass Fiber Filters, a special 4 " Diameter Stainless Steel Screen is required (included). Calibration: The rate of flow is measured by means of an indirect, variable orifice flow meter (pressure indicator gauge). This indicates the pressure drop across an orifice in the housing and is calibrated against a standard orifice on the intake. Flowrate is determined by saturation of filter paper and should be recorded accordingly during sampling test periods. User can calibrate the flow meter in the field using the US EPA prescribed method for calibrating High Volume Air Samplers, using Staplex Model CKHV and CKHV810 Calibration Kits. (See additional data sheet). General: Can be used indoors or outdoors. for mobile or fixed position operation either horizontally or vertically. Also available is a convenient Staplex TR-1 Tripod mounting. When required for protracted periods outdoors a special outdoor enclosed shelter in Aluminum (SAM) or Wooden (SWM) is available. Maintenance: TFIA series models can be operated continuously when using TFA810 and TFAGF810 8" x10" filters continuously, with filters checked and changed as need, based on particulate saturation. No lubrication of any motor parts is required. Motor brushes should be check after every 600 hours of usage and changed as needed. Changing of brushes is recommended for every 800 - 1,000 hours of usage. Accessories FiltersTFA41 Filter Paper 4" dia. (100/box) TFAGF41 Glass Fiber Filters 4" dia. (100/box) TFAQ41 Quartz Filter 4" dia. (100/box) TFA810 Filter Paper 8"x10" (100/box) TFAGF810 Glass Fiber Filters 8"x10" (100/box) TFAQ810 Quartz FIlter 8"x 10" (25/box) TFA69 Filter Paper 6"x9" (100/box) TFAGF69 Glass Fiber Filters 6"x9" (100/box) TFA2133 Filters, 4" diameter (100/box) Filter Holder
Assemblies - SH810 SH810 8" x 10" and - SH69 6" x 9" Filter Holder Assemblies, as well as additional SH4, 4" Diameter Filter Holder Assemblies are available. The larger SH69 and SH810 Filter Holder Assemblies are made of polished Stainless Steel with Dural adapter ring and filter frame. SH25 Filter Holder Assembly uses cartridge filters and is recommended for short term radioactive iodine grab sampling All Filter Holders are interchangeable, which is an essential feature when tests require the use of several samples of the same or different type filters during critical tests in which the operator can use several loaded filter holders in order to avoid contamination Flow Adjuster/Brush Seater - Models FA-1 and FA-2 - To reduce flow rate from full flow rate to desired flow rate or to "seat" new motor brushes. (see additional data sheet) Calibration Kits - Models CKHV and CKHV810 - U.S. EPA prescribed method for accurate calibration of High Volume Air Samplers. U.S. EPA recommends that High Volume Air Samplers be re-calibrated at least once per year (or when major components such as the motor or flowmeter are changed). Model CKHV used with 4" diameter filter holder assembly. Model CKHV810 used with 4" or 8" x 10" filter holder assemblies. (See additional data sheet) Where normal flat surfaces are not available for conducting air sampling tests. The Staplex® TR-1 Tripod is recommended for mounting the TFIA series High Volume Air Sampler. The Air Sampler and Tripod can be assembled and placed in any required location in a matter of minutes. Maximum extended height: 60" (152 cm) / Collapsed height: 22.5" (57 cm)
Aluminum Outdoor Shelter - Model SAM
TimersDTM-1 and DTM-2
Digital 7-Day Timer Turns Air Sampler "ON" and "OFF" at set times, 24 hours a day, 7 days a week. All functions are digital and quartz crystal controlled; includes digital clock with 1/4-in. LED display and 7.2 VDC rechargeable stand-by battery; intuitive programming format. Specify Model DTM-1 for 120 VAC, 60 Hz; Model DTM-2 for 230 VAC (specify 50 or 60 Hz when ordering). (Click to open pdf literature file)
MT-1 and MT-2 Mechanical 7 Day Timer Turns Air Sampler "ON" and "OFF" at set times ±15 minutes, 24 hours a day, 7 days a week. Specify Model MLT-1 for 120 VAC, 60 Hz; Model MLT-2 for 230 VAC, 50 Hz DTM-4CDT
Digital Countdown Timer Turns Air Sampler "OFF" or "ON" after preset times. Features LCD display and thumb-wheel setting dials. (range from 99,999 hours to 1 second). Also useable as an Elapsed Time Indicator. Size: 3" x 4-1/4" x 5" (7.6 cm x 10.8 cm x 12.7 cm); Weight: 1.75 lbs. (0.8 kg). Usable for 110-125 VAC, 220-240 VAC and 24 VDC.
ETI-1 and ETI-2 Elapsed Time Indicator Shows sampler run time in hours and hundreths (99,999.99 hours). Standard models are non-resettable mechanical models. Specify Model ETI-1 for 120 VAC, 60 Hz.; Model ETI-2 for 220 VAC, 50 Hz. (Re-settable model ETI-1R is also available for 120 VAC in minutes and tenths) Constant Flow Controllers Models FC-1 and FC-2 - Automatically maintains a constant mass flow through an High Volume Air Sampler regardless of filter loading, atmospheric conditions and line voltage. Specify Model FC-1 for 115 VAC; Model FC-2 for 230 VAC. [requires SH810 filter holder assembly] Models FC-1ETM and FC-2ETM include built-in non-resettable Elapsed Time Indicator. Models FC-1MLT and FC-2MLT include built-in Mechanical 7-Day Timer and non-resettable Elapsed Time Indicator. Flow Recorder - Models FR-1 and FR-2 - Provides a permanent record of High Volume Air Sampler performance during a 24-hour period. Specify Model FR-1 for 115 VAC; Model FR-2 for 230 VAC. (see additional data sheet)Annular Kinetic Impactor - Model AKI - designed for inertial collection especially of radioactive particles. (see additional data sheet)Carrying Cases - TFIA-CC Carrying Case for Model TFIA, TFIA-2 or TFIA-4 High Sampler and filters (includes shoulder strap).TF-CCK Carrying Case - for water proof storage and carrying of Model TFIA Air Sampler, SH810 8”x10” Filter Holder, TR-1 Tripod, Filters and other accessories. (Click to open pdf literature file)TSP (Total Suspended Particulate) Air Sampling Systems - for U.S. EPA environmental ambient air sampling (see additional data Sheet) PM10 Size Selective Inlet and Air Sampling Systems - for U.S. EPA PM10 environmental air sampling. Staplex PM10 Size Selective Inlet is available separately as Part No. PM10-SSI for conversion of existing TSP (Total Suspend Particulate) High Volume Air Sampling Systems to PM10 Systems. (see additional data sheet). (Click to open pdf literature file) High Volume Cascade Impactors, 4, 5 & 6 Stage models - for particle size separation. (see additional data sheet)
|
|
|
Home
|
Contact us
|
About Us |
Legal
Notice | Privacy
Policy
The Staplex Company, Inc. All rights reserved. Staplex, the Staplex logo, AccuSlitter and the AccuSlitter logo, Tabster and the Tabster logo are registered trademarks of The Staplex Company, Inc. Patented and patent pending items. Specifications and availability subject to change without notice or obligation. |
|||||||||||||||||||||||||||