US EPA designated method for
sampling total airborne particulates
Specifications
Model TSP-1
Total Suspended Particulate Air Sampling System, 110-125VAC
Model TSP-2
Total Suspended Particulate Air Sampling System, 220-230
VAC
(specify accessory configuration
when ordering)
Staplex® Model TSP-1 and TSP-2
Total Suspended Particulate High Volume Air Sampling System is
designed for fast, accurate collection of suspended particulates
in accordance to U.S. EPA specifications.
These complete air sampling
systems, available with various modular accessories, are designed
to meet the EPA requirements for sampling airborne particulates at
a known flow rate for a determined amount of time, allowing for
proper calculation of airborne particulate concentrations.
Basic
System
The basic Staplex®
TSP Air Sampling System includes Staplex®
High Volume Air Sampler (Model TFIA 110-120 VAC
or Model TFIA-2 220-230 VAC) with vertical mount flowmeter; SH810
8"x10" Filter Holder Assembly and SAM Aluminum Outdoor
Shelter.
Filters
- Staplex® Type
TFAGF810
8"x10" Glass Fiber Filters recommended for Total
Suspended Particulate Air Sampling
Accessory Items
Timers
DTM-1 and
DTM-2 Digital 7-Day Timer Turns
Air Sampler "ON" and "OFF" at set times, 24
hours a day, 7 days a week. All functions are digital and quartz
crystal controlled; includes digital clock with 1/4-in. LED
display and 7.2 VDC rechargeable stand-by battery; intuitive
programming format. Specify Model DTM-1 for 120 VAC, 60 Hz; Model
DTM-2 for 230 VAC (specify 50 or 60 Hz when ordering).
(see additional data sheet).
(Click to open pdf literature
file)
MT-1 and
MT-2 Mechanical 7 Day Timer Turns Air Sampler
"ON" and "OFF" at set times ±15 minutes, 24
hours a day, 7 days a week. Specify Model MLT-1 for 120 VAC, 60
Hz; Model MLT-2 for 230 VAC, 50 Hz
DTM-4CDT
Digital Countdown Timer Turns
Air Sampler "OFF" after preset times. Features LCD
display and thumb-wheel setting dials. (range from 99,999 hours to
1 second). Size: 3" x 4-1/4" x 5" (7.6 cm x 10.8 cm
x 12.7 cm); Weight: 1.75 lbs. (0.8 kg). Usable for 110-125 VAC,
220-240 VAC and 24 VDC.
ETI-1 and ETI-2
Elapsed Time Indicator Shows
sampler run time in hours and hundreths (99,999.99 hours).
Standard models are non-resettable mechanical models. Specify
Model ETI-1 for 120 VAC, 60 Hz.; Model ETI-2 for 220 VAC, 50 Hz.
(Re-settable model ETI-1R is also available for 120 VAC.)
Constant
Flow Controllers Models FC-1 and FC-2 - Automatically
maintains a constant mass flow through an High Volume Air Sampler
regardless of filter loading, atmospheric conditions and line
voltage. Specify Model FC-1 for 115 VAC; Model FC-2 for 230 VAC.
[requires SH810 filter holder assembly]
Models
FC-1ETM and FC-2ETM include built-in non-resettable Elapsed
Time Indicator.
Models
FC-1MLT and FC-2MLT include built-in Mechanical 7-Day Timer
and non-resettable Elapsed Time Indicator. (see
additional data sheet).
Flow Recorder -
Models FR-1 and FR-2 -
Provides a permanent record of High Volume Air Sampler performance
during a 24-hour period. Specify Model FR-1 for 115 VAC; Model
FR-2 for 230 VAC. (see
additional data sheet).
Calibration
Kit - Models CKHV810 - U.S.
EPA prescribed method for accurate calibration of High
Volume Air Samplers. U.S. EPA recommends
that High Volume Air Samplers be re-calibrated at least once per
year (or when major components such as the motor or flowmeter are
changed). Model CKHV810 can be used with 4" or 8" x
10" filter holder assemblies. (see
additional data sheet)
PM10 Size
Selective Inlets - for
U.S. EPA PM10 environmental air sampling. Staplex® PM10 Size
Selective Inlet is available separately as Part No. PM10-SSI for
conversion of existing TSP (Total Suspend Particulate) High Volume
Air Sampling Systems to PM10 System.
(see
additional data sheet)
4, 5 & 6
Stage High Volume Cascade Impactors - for
particle size separation
(see
additional data sheet)
|