TSP* & PM10 Environmental Air Sampler
Systems
Staplex® Critical Flow
(Volumetric) High Volume Air Sampler System
for Total Suspended Particulates and PM10
Models TSP-CF
(110 V), TSP-CF-2 (220 V)
FEATURES:
- Constant Volumetric Flow Rate
without anymoving
parts or electronic components
- Complies with U.S. EPA
Reference
- Method (40 CFR Part 50
Appendix B)
- Durable design for outdoor use
- Most complete system available
- Made in U.S.A.
STANDARD COMPONENTS:
- Special High Volume Air
Sampler
- Critical Flow Device
- 8" x 10" Filter
Folder with Filter Paper Cartridge
- Aluminum Outdoor Shelter
Recommended
accessories:
- Mechanical or Digital Timer
(specify preference when ordering)
- Elapsed Time Indicator
Staplex® Model TSP-CF and
TSP-CF-2 Critical Flow High Volume Air Sampler Systems are
designed for Total Suspended Particulate (TSP) ambient air
sampling for compliance with U.S. EPA Reference Method.
The Critical Flow Device is a
dimensional venture used to control gas flow, When applied to a
high volume air sampler, this flow control principle incorporates
a smooth-wall venture orifice that gradually opens to a recovery
section. Vacuum is provided by a motor downstream of the venture.
Over 95% of the energy lost in differential pressures across the
restricting orifice is recovered by this design,
Flow control is accomplished by
occluding (restricting) and thus accelerating the air flow through
the venture. At some point in the flow stream, the air velocity
will equal the acoustic velocity or speed of sound in the throat
(smallest diameter portion), and "critical flow " will
be achieved. At the critical flow point, the critical flow device
will not allow more air through under existing temperature and
pressure conditions. As long as downstream changes are small, all
conditions at the venturi (including the flow rate) are determined
by upstream conditions. This condition is referred to as “choking"
and is a distinctive characteristic of all volumetric critical
flow devices.
The Staplex® Critical Flow
High Volume Air Sampling Systems use this principle of choke to
maintain a constant actual flow rate of 40 cubic feet per minute
(1.13 cubic meters per minute) over a sample period. Since
critical flow through the venturi is not greatly affected by
changes in filter loading, ambient temperture or barometric
pressure, a stable volumetric flow rate is maintained as long as
power is provided to the sampler. The critical flow device
regulates flow at a constant but unadjustable rate without any
moving parts or electronic components.
Ordering Information:
(specify components when ordering)
Staplex®
Model TSP-CF Critical Flow High Volume Air Sampler System
(110 Volts)
Staplex®
Model TSP-CF-2 Critical Flow High Volume Air Sampler System
(220 Volts)
[Shipping Weight: 75-lbs. (34
kg)]
Filters:
Staplex® Type
TFAGF810 Glass Fiber Filters, 8" x 10"
(100/box)
Optional Accessories:
Flow Recorder -
Models FR-1 and FR-2 -
Provides a permanent record of High Volume Air Sampler performance
during a 24-hour period. Specify Model FR-1 for 115 VAC; Model
FR-2 for 230 VAC. (see
additional data sheet).
Timers -
DTM-1 and
DTM-2 Digital 7-Day Timer - Turns
Air Sampler "ON" and "OFF" at set times, 24
hours a day, 7 days a week. All functions are digital and quartz
crystal controlled; digital clock with 1/4-in. LED display and 7.2
VDC re-chargeable stand-by battery; intuitive programming format.
Specify Model DTM-1 for 120 VAC, 60 Hz; Model DTM-2 for 230 VAC
(specify 50 or 60 Hz when ordering).
(Click
to open pdf literature file)
MT-1 and MT-2
Mechanical 7 Day Timer Turns
Air Sampler "ON" and "OFF" at set times ± 15
minutes, 24 hours a day, 7 days a week. Specify Model MLT-1 for
120 VAC, 60 Hz; Model MLT-2 for 230 VAC, 50 Hz
ETI-1 (120 VAC)
/ETI-2 (220 VAC) Elapsed Time Indicator
- (without Flow Controller) Shows sampler
run time in hours and hundreths (99,999.99 hours,
mechanical non-resettable). (Re-settable
model ETI-1R is also available for 120 VAC.)
Calibration
Kit - Models CKHV810 - U.S.
EPA prescribed method for accurate calibration of High
Volume Air Samplers. U.S. EPA recommends
that High Volume Air Samplers be re-calibrated at least once per
year (or when major components such as the motor or flowmeter are
changed). Model CKHV810 can be used with 4" or 8" x
10" filter holder assemblies. (see
additional data sheet)
PM10 Size
Selective Inlets -
for U.S. EPA PM10 environmental air sampling. Staplex® PM10 Size
Selective Inlet is available separately as Part No. PM10-SSI for
conversion of existing TSP (Total Suspend Particulate) High Volume
Air Sampling Systems to PM10 System. (see
additional data sheet)
4, 5 & 6
Stage High Volume Cascade Impactors - for
particle size separation
(see additional data sheet)